		<item>
			<title><![CDATA[Démarrage des recherches matériels et cablage]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13667</link>
			<pubDate>Fri, 15 May 2026 12:59:25 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14934">oliv189@yahoo.fr</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13667</guid>
			<description><![CDATA[Bonjour à tous,<br />
Je suis actuellement en phase de validation des <span style="font-weight: bold;" class="mycode_b">plans physiques de ma future maison</span>, et je souhaite anticiper au maximum la partie domotique dès la conception.<br />
Mon objectif est de <span style="font-weight: bold;" class="mycode_b">prévoir une installation la plus filaire possible</span>, fiable et évolutive, en intégrant dès le départ les principaux postes :<ul class="mycode_list"><li>électricité / éclairage ; <br />
</li>
<li>chauffage ; <br />
</li>
<li>solaire / gestion de l’énergie ; <br />
</li>
<li>alarme ; <br />
</li>
<li>gestion de l’eau ; <br />
</li>
<li>piscine ; <br />
</li>
<li>porte d’entrée ; <br />
</li>
<li>porte sectionnelle de garage ; <br />
</li>
<li>volets / protections solaires ; <br />
</li>
<li>éventuelle supervision type Home Assistant. <br />
</li>
</ul>
Je souhaite éviter de devoir “bricoler” après coup avec trop de modules sans fil, et j’aimerais donc bien dimensionner les gaines, câbles, tableaux, bus, réserves et interfaces dès maintenant.<br />
J’ai déjà suivi la formation disponible sur <span style="font-weight: bold;" class="mycode_b">knx.org</span>, mais j’aurais besoin de retours d’expérience pour savoir :<br />
<ol type="1" class="mycode_list"><li>Quels éléments prévoir impérativement dès la phase de plans ? <br />
</li>
<li>Quels câblages tirer en priorité ? <br />
</li>
<li>Quels équipements ou marques recommandez-vous pour une installation KNX filaire fiable ? <br />
</li>
<li>Quels sont les pièges à éviter avant le passage de l’électricien ? <br />
</li>
<li>Faut-il prévoir un tableau domotique séparé ou surdimensionné ? <br />
</li>
<li>Comment bien intégrer ensuite l’alarme, le chauffage, le solaire, la piscine et la gestion de l’eau ? <br />
</li>
<li>Est-il pertinent d’acheter dès maintenant <span style="font-weight: bold;" class="mycode_b">ETS6 Pro</span>, ou vaut-il mieux commencer avec une version plus limitée type ETS Home selon la taille du projet ? <br />
</li>
</ol>
Je cherche vraiment à construire une base propre, durable et évolutive, avec une logique plutôt <span style="font-weight: bold;" class="mycode_b">KNX en colonne vertébrale</span> et éventuellement <span style="font-weight: bold;" class="mycode_b">Home Assistant en supervision</span>.<br />
Merci d’avance pour vos conseils, retours d’expérience et recommandations.]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
Je suis actuellement en phase de validation des <span style="font-weight: bold;" class="mycode_b">plans physiques de ma future maison</span>, et je souhaite anticiper au maximum la partie domotique dès la conception.<br />
Mon objectif est de <span style="font-weight: bold;" class="mycode_b">prévoir une installation la plus filaire possible</span>, fiable et évolutive, en intégrant dès le départ les principaux postes :<ul class="mycode_list"><li>électricité / éclairage ; <br />
</li>
<li>chauffage ; <br />
</li>
<li>solaire / gestion de l’énergie ; <br />
</li>
<li>alarme ; <br />
</li>
<li>gestion de l’eau ; <br />
</li>
<li>piscine ; <br />
</li>
<li>porte d’entrée ; <br />
</li>
<li>porte sectionnelle de garage ; <br />
</li>
<li>volets / protections solaires ; <br />
</li>
<li>éventuelle supervision type Home Assistant. <br />
</li>
</ul>
Je souhaite éviter de devoir “bricoler” après coup avec trop de modules sans fil, et j’aimerais donc bien dimensionner les gaines, câbles, tableaux, bus, réserves et interfaces dès maintenant.<br />
J’ai déjà suivi la formation disponible sur <span style="font-weight: bold;" class="mycode_b">knx.org</span>, mais j’aurais besoin de retours d’expérience pour savoir :<br />
<ol type="1" class="mycode_list"><li>Quels éléments prévoir impérativement dès la phase de plans ? <br />
</li>
<li>Quels câblages tirer en priorité ? <br />
</li>
<li>Quels équipements ou marques recommandez-vous pour une installation KNX filaire fiable ? <br />
</li>
<li>Quels sont les pièges à éviter avant le passage de l’électricien ? <br />
</li>
<li>Faut-il prévoir un tableau domotique séparé ou surdimensionné ? <br />
</li>
<li>Comment bien intégrer ensuite l’alarme, le chauffage, le solaire, la piscine et la gestion de l’eau ? <br />
</li>
<li>Est-il pertinent d’acheter dès maintenant <span style="font-weight: bold;" class="mycode_b">ETS6 Pro</span>, ou vaut-il mieux commencer avec une version plus limitée type ETS Home selon la taille du projet ? <br />
</li>
</ol>
Je cherche vraiment à construire une base propre, durable et évolutive, avec une logique plutôt <span style="font-weight: bold;" class="mycode_b">KNX en colonne vertébrale</span> et éventuellement <span style="font-weight: bold;" class="mycode_b">Home Assistant en supervision</span>.<br />
Merci d’avance pour vos conseils, retours d’expérience et recommandations.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Nouveau passionné domotique & sécurité - Bonjour à tous !]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13475</link>
			<pubDate>Mon, 04 May 2026 13:02:37 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14758">Seb_IoT</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13475</guid>
			<description><![CDATA[Bonjour à toute la communauté !   <img src="https://www.knx-fr.com/images/smilies/wink.gif" alt="Wink" title="Wink" class="smilie smilie_2" /> <br />
<br />
Moi c'est Seb, je suis dans l'informatique et les réseaux depuis quelques années, et je mets enfin sérieusement les mains dans le cambouis de la domotique. <br />
<br />
Je rejoins le forum car je suis en pleine phase d'apprentissage sur le standard KNX. J'ai longtemps bidouillé avec des solutions sans fil grand public, mais je veux passer à un système robuste et pérenne pour mon projet d'installation.<br />
<br />
Mon petit "tic" professionnel, c'est la cybersécurité. Du coup, en abordant le KNX, je m'intéresse énormément à la façon dont on sécurise les accès distants, comment on isole le réseau domotique du réseau internet classique, et la gestion de KNX Secure. C'est fascinant de voir comment le monde du bâtiment et celui de l'IT se rejoignent !<br />
<br />
J'ai déjà parcouru pas mal de vos anciens sujets (une vraie mine d'or, bravo aux contributeurs), mais je risque de vous embêter bientôt avec des questions un peu pointues sur la sécurisation des passerelles IP.  <img src="https://www.knx-fr.com/images/smilies/biggrin.gif" alt="Big Grin" title="Big Grin" class="smilie smilie_4" /> <br />
<br />
Au plaisir d'échanger avec vous et d'apprendre de vos retours d'expérience !]]></description>
			<content:encoded><![CDATA[Bonjour à toute la communauté !   <img src="https://www.knx-fr.com/images/smilies/wink.gif" alt="Wink" title="Wink" class="smilie smilie_2" /> <br />
<br />
Moi c'est Seb, je suis dans l'informatique et les réseaux depuis quelques années, et je mets enfin sérieusement les mains dans le cambouis de la domotique. <br />
<br />
Je rejoins le forum car je suis en pleine phase d'apprentissage sur le standard KNX. J'ai longtemps bidouillé avec des solutions sans fil grand public, mais je veux passer à un système robuste et pérenne pour mon projet d'installation.<br />
<br />
Mon petit "tic" professionnel, c'est la cybersécurité. Du coup, en abordant le KNX, je m'intéresse énormément à la façon dont on sécurise les accès distants, comment on isole le réseau domotique du réseau internet classique, et la gestion de KNX Secure. C'est fascinant de voir comment le monde du bâtiment et celui de l'IT se rejoignent !<br />
<br />
J'ai déjà parcouru pas mal de vos anciens sujets (une vraie mine d'or, bravo aux contributeurs), mais je risque de vous embêter bientôt avec des questions un peu pointues sur la sécurisation des passerelles IP.  <img src="https://www.knx-fr.com/images/smilies/biggrin.gif" alt="Big Grin" title="Big Grin" class="smilie smilie_4" /> <br />
<br />
Au plaisir d'échanger avec vous et d'apprendre de vos retours d'expérience !]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Remplacement Interrupteur KNX]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13461</link>
			<pubDate>Sat, 02 May 2026 16:04:26 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14724">midimlansound</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13461</guid>
			<description><![CDATA[Bonjour, <br />
<br />
On a a acheter il y a une dizaine d'années un appartement entièrement installé en KNX. Aucun problème électrique ,Fiabilité . Bref , C'est génial. Cependant un de mes interrupteur ne fonctionne plus (microswitch cassé). <br />
J'ai trouvé le même interrupteur chez Schneider. cependant le j'ai pas le fichier ETS de conf  et pas ETS. <br />
<br />
Quels les moyens de copier l'adresse dans l'ancien interrupteur vers le nouveau (s'il y en a ) pour pouvoir avoir une commande fonctionnelle?]]></description>
			<content:encoded><![CDATA[Bonjour, <br />
<br />
On a a acheter il y a une dizaine d'années un appartement entièrement installé en KNX. Aucun problème électrique ,Fiabilité . Bref , C'est génial. Cependant un de mes interrupteur ne fonctionne plus (microswitch cassé). <br />
J'ai trouvé le même interrupteur chez Schneider. cependant le j'ai pas le fichier ETS de conf  et pas ETS. <br />
<br />
Quels les moyens de copier l'adresse dans l'ancien interrupteur vers le nouveau (s'il y en a ) pour pouvoir avoir une commande fonctionnelle?]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Bonjour!]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13460</link>
			<pubDate>Sat, 02 May 2026 11:58:03 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14655">Cispontine</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13460</guid>
			<description><![CDATA[Bonjour tout le monde,<br />
Je m'appelle Irene, je suis actuellement une formation AFPA en électricité et domotique. A titre personnel, je suis en train de faire construire donc tout se regroupe pour que je puisse faire ma première installation KNX.<br />
<br />
Bonne continuation à tous.]]></description>
			<content:encoded><![CDATA[Bonjour tout le monde,<br />
Je m'appelle Irene, je suis actuellement une formation AFPA en électricité et domotique. A titre personnel, je suis en train de faire construire donc tout se regroupe pour que je puisse faire ma première installation KNX.<br />
<br />
Bonne continuation à tous.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Actionneur pour électrovannes + LED]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13246</link>
			<pubDate>Sun, 26 Apr 2026 20:09:00 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=12339">gromk</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13246</guid>
			<description><![CDATA[Bonjour à tous,<br />
<br />
Après des mois de maturation, je vais prochainement acheter les premières briques de mon installation KNX. Une fois n'est pas coutume, j'ai commencé par l'extérieur.<br />
<br />
Ayant peu de place dans le tableau de mon local, j'aimerais grouper dans un même actionneur TOR (soit 4 soit 8 sorties) :<br />
- la commande des 4 électrovannes : l'alimentation 24V se ferait via une centrale d'arrosage classique (Hunter ou Rainbird ou assimilé), et j'utiliserai soit 1 actionneur TOR sur le fil commun pour couper l'arrosage s'il pleut ou va pleuvoir, ou carrément 4 actionneurs TOR pour bypasser totalement la centrale si je souhaite (il suffirait de lui dire d'arroser 7j/7 24h/24 et de laisser le contrôle à KNX).<br />
- l'éclairage : 3 lignes d'éclairage LED indépendantes<br />
<br />
J'ai relevé les contraintes suivantes pour le cahier des charges de l'actionneur :<br />
- pouvoir gérer du 24V et du 230V indifféremment<br />
- pouvoir gérer le courant d'appel des LEDs<br />
- bonus : avoir également 1 à 4 entrées pour des interrupteurs<br />
<br />
Y a-t-il autre chose d'important ?<br />
Plus généralement, y a-t-il une raison majeure qui m'empêcherait de grouper la commande des électrovannes et des LEDs ?<br />
<br />
Bonus : si vous connaissez une référence adéquate, je suis preneur.<br />
<br />
Merci et bon dimanche.]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
<br />
Après des mois de maturation, je vais prochainement acheter les premières briques de mon installation KNX. Une fois n'est pas coutume, j'ai commencé par l'extérieur.<br />
<br />
Ayant peu de place dans le tableau de mon local, j'aimerais grouper dans un même actionneur TOR (soit 4 soit 8 sorties) :<br />
- la commande des 4 électrovannes : l'alimentation 24V se ferait via une centrale d'arrosage classique (Hunter ou Rainbird ou assimilé), et j'utiliserai soit 1 actionneur TOR sur le fil commun pour couper l'arrosage s'il pleut ou va pleuvoir, ou carrément 4 actionneurs TOR pour bypasser totalement la centrale si je souhaite (il suffirait de lui dire d'arroser 7j/7 24h/24 et de laisser le contrôle à KNX).<br />
- l'éclairage : 3 lignes d'éclairage LED indépendantes<br />
<br />
J'ai relevé les contraintes suivantes pour le cahier des charges de l'actionneur :<br />
- pouvoir gérer du 24V et du 230V indifféremment<br />
- pouvoir gérer le courant d'appel des LEDs<br />
- bonus : avoir également 1 à 4 entrées pour des interrupteurs<br />
<br />
Y a-t-il autre chose d'important ?<br />
Plus généralement, y a-t-il une raison majeure qui m'empêcherait de grouper la commande des électrovannes et des LEDs ?<br />
<br />
Bonus : si vous connaissez une référence adéquate, je suis preneur.<br />
<br />
Merci et bon dimanche.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Changement de centrale d'alarme > blocage des volets roulants]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13229</link>
			<pubDate>Mon, 20 Apr 2026 09:06:06 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14586">crateau</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13229</guid>
			<description><![CDATA[Bonjour à tous,<br />
<br />
Je viens à votre rencontre pour avoir des idées de résolution de problème après 10 bonnes journées sans parvenir à identifier ce qui coince : amis des jeux de piste et des intrigues à rebondissements, bienvenue.<br />
<br />
La maison est équipée en Hager, avec un serveur Domovea V1 et paramétrée sur ETS5. On retrouve principalement en terme de matériel :<ul class="mycode_list"><li>Interfaces ABB US/U2.2 ou 4.2 <br />
</li>
<li>Actionneurs de jalousies simples 6152/11-500<br />
</li>
<li>Et des modules TXA 610B 207C 610B<br />
</li>
</ul>
<br />
En y passant un peu de temps il y a 5 ans j'ai pu récupérer les accès au configurateur Domovea et au projet ETS5, via une interface IP pour le premier et un module USB Tebis pour le second et les documents retrouvés.<br />
<br />
Tout a commencé il y a 15 jours lorsque j'ai changé la centrale d'alarme en place qui était une Paradox Evo 192 avec un module Tokka, qui utilisait donc une imprimante virtuelle pour envoyer les télégrammes de détection et de statut des zones.<br />
<br />
Une fois la dépose de l'ancienne centrale effectuée, j'ai installé la nouvelle (AJAX) et remplacé le module Tokka par 4 relais en contacts secs reliés à une interface ABB pour avoir une remontée d'informations (armement / désarmement).<br />
<br />
Depuis cette opération : aucun volet roulant du RDC ne fonctionne &gt; pas de réaction lors de l'appui sur les interrupteurs correspondants, ni via Domovea.<br />
<br />
Après scan de la ligne en question, les actionneurs des VR du RDC sont tous hors ligne du bus. Je trouve aussi 2 dispositifs inconnus physiquement présents sur la ligne et adressés mais pas enregistrés dans le projet ETS5, en plus de quelques dispositifs déclarés dans ETS5 mais non présents sur le bus qui pourraient juste être des reliquats d'installation.<br />
<br />
Pour rendre l'opération encore plus complexe, les actionneurs des VR sont encastrés donc impossible d'accès sans endommager le placo et la peinture, donc je cherche depuis 10 jours une solution informatique sans pouvoir vérifier physiquement l'absence de tension de bus ou de ligne 230V.<br />
<br />
J'ai d'abord vérifié la ligne 230V (tous les VR sont sur le même disjoncteur par étage) sans rien constater, puis je me suis dit que pendant les travaux au tableau électrique (proche de la centrale d'alarme) j'avais coupé le bus mais rien non plus, tout semble OK.<br />
<br />
Il est possible qu'il était paramétré une sorte de système d'auto-protection relié à l'alarme avec ce scénario : en cas d'alarme audible / intrusion confirmée alors les actionneurs des VR se neutralisent pour "bloquer" un cambrioleur qui serait rentré par les étages supérieurs et l'empêcher de sortir par le RDC. C'est la seule solution que je vois tellement c'est "trop beau" pour que pile tous les actionneurs VR de l'étage soient hors-ligne ensemble.<br />
<br />
De ma compréhension, c'est la centrale Paradox qui devait émettre via le module Tokka les bons télégrammes pour sortir les actionneurs du bus, soit physiquement (interrupteur ?) soit informatiquement (coupleur de ligne ? serveur caché ? scène ? masque de sous réseau ?) et les réintégrer lorsque l'alarme cesse. Je pense qu'en changeant de centrale, et en envoyant le télégramme "0/3/2 Secteur Armé" il y a eu blocage des actionneurs (sortie du bus) et que le système croit encore que l'alarme est active à défaut de recevoir le télégramme qu'il attend par exemple "Prêt pour armer". <br />
<br />
Depuis 10 jours j'ai essayé d'envoyer manuellement sur la ligne des télégrammes dans les adresses qui semblaient utilisées par Paradox (activé / désactivé) et de scruter le bus : j'ai bien l'impression qu'il se passe "quelque chose" en réaction sans que je puisse identifier quoi. Je cherche aussi des dispositifs qui pourraient servir à couper le bus des VR sans pouvoir les identifier.<br />
<br />
Sur Domovea Configurateur aucun automatisme ne semble  tourner, et je ne vois pas d'action Routeur IP/KNX en scrutant le bus. Mais il y a des variables crées type "Alarme mise" "Non-bloqué" dont je ne sais pas quoi faire.<br />
<br />
Périodiquement, je vois aussi passer des commandes sur le bus, sans action physique sur les interrupteur bien entendu (en désactivation ou activation). Elles viennent directement des interfaces ABB (en nom de la source) qui semblent remonter leur état (envoyer désactivé lorsqu'ils sont désactivés) et ne semblent pas passer par Domovea.<br />
<br />
Ma question est donc la suivante : je suis à la recherche de la source de ces commandes qui se baladent, et donc des adresses qui pourraient les influencer pour comprendre comment les actionneurs des VR sortent et entrent dans le bus en fonction. <br />
<br />
J'ai rien trouvé sur Domovea mais peut-être qu'il existe un configurateur "caché" par exemple accessible uniquement en USB et pas via le Wifi pour trouver ces automatismes cachés  ?<br />
<br />
Ou bien ce serait sur ETS avec par exemple des scènes KNX mais je ne sais pas où les trouver non plus... <br />
<br />
Je sollicite votre aide pour m'aider à me poser les bonnes questions et regarder au bon endroit pour résoudre cette énigme : dispositif qui coupe le bus des actionneurs, actionneurs qui sortent informatiquement du réseau, automatisme ou scène cachée...<br />
<br />
Bonne journée à tous !]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
<br />
Je viens à votre rencontre pour avoir des idées de résolution de problème après 10 bonnes journées sans parvenir à identifier ce qui coince : amis des jeux de piste et des intrigues à rebondissements, bienvenue.<br />
<br />
La maison est équipée en Hager, avec un serveur Domovea V1 et paramétrée sur ETS5. On retrouve principalement en terme de matériel :<ul class="mycode_list"><li>Interfaces ABB US/U2.2 ou 4.2 <br />
</li>
<li>Actionneurs de jalousies simples 6152/11-500<br />
</li>
<li>Et des modules TXA 610B 207C 610B<br />
</li>
</ul>
<br />
En y passant un peu de temps il y a 5 ans j'ai pu récupérer les accès au configurateur Domovea et au projet ETS5, via une interface IP pour le premier et un module USB Tebis pour le second et les documents retrouvés.<br />
<br />
Tout a commencé il y a 15 jours lorsque j'ai changé la centrale d'alarme en place qui était une Paradox Evo 192 avec un module Tokka, qui utilisait donc une imprimante virtuelle pour envoyer les télégrammes de détection et de statut des zones.<br />
<br />
Une fois la dépose de l'ancienne centrale effectuée, j'ai installé la nouvelle (AJAX) et remplacé le module Tokka par 4 relais en contacts secs reliés à une interface ABB pour avoir une remontée d'informations (armement / désarmement).<br />
<br />
Depuis cette opération : aucun volet roulant du RDC ne fonctionne &gt; pas de réaction lors de l'appui sur les interrupteurs correspondants, ni via Domovea.<br />
<br />
Après scan de la ligne en question, les actionneurs des VR du RDC sont tous hors ligne du bus. Je trouve aussi 2 dispositifs inconnus physiquement présents sur la ligne et adressés mais pas enregistrés dans le projet ETS5, en plus de quelques dispositifs déclarés dans ETS5 mais non présents sur le bus qui pourraient juste être des reliquats d'installation.<br />
<br />
Pour rendre l'opération encore plus complexe, les actionneurs des VR sont encastrés donc impossible d'accès sans endommager le placo et la peinture, donc je cherche depuis 10 jours une solution informatique sans pouvoir vérifier physiquement l'absence de tension de bus ou de ligne 230V.<br />
<br />
J'ai d'abord vérifié la ligne 230V (tous les VR sont sur le même disjoncteur par étage) sans rien constater, puis je me suis dit que pendant les travaux au tableau électrique (proche de la centrale d'alarme) j'avais coupé le bus mais rien non plus, tout semble OK.<br />
<br />
Il est possible qu'il était paramétré une sorte de système d'auto-protection relié à l'alarme avec ce scénario : en cas d'alarme audible / intrusion confirmée alors les actionneurs des VR se neutralisent pour "bloquer" un cambrioleur qui serait rentré par les étages supérieurs et l'empêcher de sortir par le RDC. C'est la seule solution que je vois tellement c'est "trop beau" pour que pile tous les actionneurs VR de l'étage soient hors-ligne ensemble.<br />
<br />
De ma compréhension, c'est la centrale Paradox qui devait émettre via le module Tokka les bons télégrammes pour sortir les actionneurs du bus, soit physiquement (interrupteur ?) soit informatiquement (coupleur de ligne ? serveur caché ? scène ? masque de sous réseau ?) et les réintégrer lorsque l'alarme cesse. Je pense qu'en changeant de centrale, et en envoyant le télégramme "0/3/2 Secteur Armé" il y a eu blocage des actionneurs (sortie du bus) et que le système croit encore que l'alarme est active à défaut de recevoir le télégramme qu'il attend par exemple "Prêt pour armer". <br />
<br />
Depuis 10 jours j'ai essayé d'envoyer manuellement sur la ligne des télégrammes dans les adresses qui semblaient utilisées par Paradox (activé / désactivé) et de scruter le bus : j'ai bien l'impression qu'il se passe "quelque chose" en réaction sans que je puisse identifier quoi. Je cherche aussi des dispositifs qui pourraient servir à couper le bus des VR sans pouvoir les identifier.<br />
<br />
Sur Domovea Configurateur aucun automatisme ne semble  tourner, et je ne vois pas d'action Routeur IP/KNX en scrutant le bus. Mais il y a des variables crées type "Alarme mise" "Non-bloqué" dont je ne sais pas quoi faire.<br />
<br />
Périodiquement, je vois aussi passer des commandes sur le bus, sans action physique sur les interrupteur bien entendu (en désactivation ou activation). Elles viennent directement des interfaces ABB (en nom de la source) qui semblent remonter leur état (envoyer désactivé lorsqu'ils sont désactivés) et ne semblent pas passer par Domovea.<br />
<br />
Ma question est donc la suivante : je suis à la recherche de la source de ces commandes qui se baladent, et donc des adresses qui pourraient les influencer pour comprendre comment les actionneurs des VR sortent et entrent dans le bus en fonction. <br />
<br />
J'ai rien trouvé sur Domovea mais peut-être qu'il existe un configurateur "caché" par exemple accessible uniquement en USB et pas via le Wifi pour trouver ces automatismes cachés  ?<br />
<br />
Ou bien ce serait sur ETS avec par exemple des scènes KNX mais je ne sais pas où les trouver non plus... <br />
<br />
Je sollicite votre aide pour m'aider à me poser les bonnes questions et regarder au bon endroit pour résoudre cette énigme : dispositif qui coupe le bus des actionneurs, actionneurs qui sortent informatiquement du réseau, automatisme ou scène cachée...<br />
<br />
Bonne journée à tous !]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Compatibilité KNX / DEVIALET]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13205</link>
			<pubDate>Sat, 11 Apr 2026 16:34:34 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=14509">Franck_92</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13205</guid>
			<description><![CDATA[Bonjour,<br />
<br />
Actuellement à l'étude de l'achat d'une maison entièrement installée avec une domotique KNX, je voudrais savoir si certains d'entre vous ont déjà expérimenter l'intégration de produits Devialet avec une installation KNX ?!<br />
<br />
suis preneur de tout retour d'expérience bon ou mauvais <img src="https://www.knx-fr.com/images/smilies/wink.gif" alt="Wink" title="Wink" class="smilie smilie_2" /><br />
<br />
Merci à tous et bon week-end]]></description>
			<content:encoded><![CDATA[Bonjour,<br />
<br />
Actuellement à l'étude de l'achat d'une maison entièrement installée avec une domotique KNX, je voudrais savoir si certains d'entre vous ont déjà expérimenter l'intégration de produits Devialet avec une installation KNX ?!<br />
<br />
suis preneur de tout retour d'expérience bon ou mauvais <img src="https://www.knx-fr.com/images/smilies/wink.gif" alt="Wink" title="Wink" class="smilie smilie_2" /><br />
<br />
Merci à tous et bon week-end]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[[VENDU] MDT AKH-0800.03]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13200</link>
			<pubDate>Thu, 09 Apr 2026 19:38:17 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=4860">poukill</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13200</guid>
			<description><![CDATA[Bonjour,<br />
<br />
Je le vends sur le BonCoin <a href="https://www.leboncoin.fr/ad/bricolage/3176804053" target="_blank" rel="noopener" class="mycode_url">ici</a><br />
Jamais servi ! <img src="https://www.knx-fr.com/images/smilies/smile.gif" alt="Smile" title="Smile" class="smilie smilie_1" />]]></description>
			<content:encoded><![CDATA[Bonjour,<br />
<br />
Je le vends sur le BonCoin <a href="https://www.leboncoin.fr/ad/bricolage/3176804053" target="_blank" rel="noopener" class="mycode_url">ici</a><br />
Jamais servi ! <img src="https://www.knx-fr.com/images/smilies/smile.gif" alt="Smile" title="Smile" class="smilie smilie_1" />]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[HA & Hager TE331]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13198</link>
			<pubDate>Thu, 09 Apr 2026 14:53:01 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=2645">pollux06</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13198</guid>
			<description><![CDATA[Comme je me suis mis depuis peu à Home assistant, je suis entrain d'intégrer dans HA toutes mes GA KNX.<br />
<br />
Etant donné que je ne suis pas encore très au point en HA, est-ce que l'un d'entre vous aurait déjà intégré ce "compteur" et si oui pourriez-vous m'indiquer les différentes étapes à suivre ?<br />
<br />
Merci par avance.]]></description>
			<content:encoded><![CDATA[Comme je me suis mis depuis peu à Home assistant, je suis entrain d'intégrer dans HA toutes mes GA KNX.<br />
<br />
Etant donné que je ne suis pas encore très au point en HA, est-ce que l'un d'entre vous aurait déjà intégré ce "compteur" et si oui pourriez-vous m'indiquer les différentes étapes à suivre ?<br />
<br />
Merci par avance.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Sonde monoxyde de carbone (CO)]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13196</link>
			<pubDate>Thu, 09 Apr 2026 07:26:27 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=2645">pollux06</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13196</guid>
			<description><![CDATA[Bonjour à tous,<br />
<br />
Ca fait déjà pas mal de temps que je suis à la recherche d'un détecteur de monoxyde de carbone en full KNX.<br />
Je trouve sans problème une foultitude de sondes de gaz carbonique (CO2) mais rien pour le monoxyde de carbone (CO).<br />
<br />
Comme il n'y a aucune corrélation entre ces 2 gaz, (le CO est mortel mais pas le CO2) on ne peut pas mettre une sonde de CO2 et estimer la quantité de CO.<br />
<br />
Il y a bien entendu la solution de prendre un détecteur de CO non KNX et relier les bornes de l'alarme à un système de contacts secs lui même relié à un ABB/UKS ...... mais j'aurais voulu un système full KNX pour le mettre dans les pièces susceptibles de générer du CO (chaufferie, pièces avec cheminée ou poêle à bois) <br />
<br />
Vous utilisez quoi pour la détection du CO ?]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
<br />
Ca fait déjà pas mal de temps que je suis à la recherche d'un détecteur de monoxyde de carbone en full KNX.<br />
Je trouve sans problème une foultitude de sondes de gaz carbonique (CO2) mais rien pour le monoxyde de carbone (CO).<br />
<br />
Comme il n'y a aucune corrélation entre ces 2 gaz, (le CO est mortel mais pas le CO2) on ne peut pas mettre une sonde de CO2 et estimer la quantité de CO.<br />
<br />
Il y a bien entendu la solution de prendre un détecteur de CO non KNX et relier les bornes de l'alarme à un système de contacts secs lui même relié à un ABB/UKS ...... mais j'aurais voulu un système full KNX pour le mettre dans les pièces susceptibles de générer du CO (chaufferie, pièces avec cheminée ou poêle à bois) <br />
<br />
Vous utilisez quoi pour la détection du CO ?]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Retour d'état volets Zigbee -> KNX sur Home assistant]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13194</link>
			<pubDate>Tue, 31 Mar 2026 17:50:12 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=5676">BigYo</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13194</guid>
			<description><![CDATA[Bonjour,<br />
<br />
Je viens de migrer vers Home assistant depuis Jeedom. J'ai intégré 99% de mes appareils, mais je bute encore sur une chose : mes volets roulants ZigBee  <img src="https://www.knx-fr.com/images/smilies/dodgy.gif" alt="Dodgy" title="Dodgy" class="smilie smilie_14" /><br />
<br />
Ils remontent sur HA via un dongle SLZB-06, aucun problème à ce niveau. <br />
J'arrive à les piloter depuis mes boutons KNX aussi via Node Red, pas de problème particulier non plus.<br />
<br />
Par contre, j'ai un soucis avec le retour d'état sur mes écrans tactiles Schneider Multitouch qui ont affichage visuel type curseurs :<br />
<a href="https://postimg.cc/JD0J4xb6" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/JD0J4xb6/Curseur.jpg" loading="lazy"  alt="[Image: Curseur.jpg]" class="mycode_img" /></a><br />
<br />
Lorsque j'envoie ma commande, le retour d'état ne se fait pas. Plus précisément :<br />
- lorsque je change le position d'un volet sur un écran, la position ne suit pas sur le second (ils pilotent les mêmes volets)<br />
- lorsque je change la position d'un volet sur HA, la position ne suit sur aucun des deux<br />
<br />
Par contre, sur mon moniteur de bus, j'ai bien un groupvalueWrite de la valeur de la position du volet qui remonte sur mon GA.<br />
<br />
Je pense qu'il doit y avoir un problème au niveau de ma config de retour d'état sur Node Red, et le bus KNX ne doit pas lire/recevoir l'info correctement. Mais étant clairement novice sur HA, je sèche :/<br />
<br />
Je vous mets mes GA depuis ETS (pour un volet, mais identique pour tous) :<br />
<img src="https://i.postimg.cc/q75FWGf5/GA-ETS.jpg" loading="lazy"  alt="[Image: GA-ETS.jpg]" class="mycode_img" /><br />
Et ma config sous Node Red :<br />
<img src="https://i.postimg.cc/htJG7c8m/Node-red.jpg" loading="lazy"  alt="[Image: Node-red.jpg]" class="mycode_img" /><br />
<br />
Et mes noeuds :<br />
<br />
Event : states<br />
[img]<a href="https://i.postimg.cc/9RK0T8FW" target="_blank" rel="noopener" class="mycode_url">https://i.postimg.cc/9RK0T8FW/Event-1.jpg</a>[/img]<br />
[img]<a href="https://i.postimg.cc/r03sWny7/Event-2.jpg" target="_blank" rel="noopener" class="mycode_url">https://i.postimg.cc/r03sWny7/Event-2.jpg</a>[/img]<br />
<br />
Change :<br />
<a href="https://postimg.cc/G8H94wRZ" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/G8H94wRZ/Change.jpg" loading="lazy"  alt="[Image: Change.jpg]" class="mycode_img" /></a><br />
<br />
<br />
KNX Device :<br />
<a href="https://postimg.cc/ph4r8GV4" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/ph4r8GV4/KNX1.jpg" loading="lazy"  alt="[Image: KNX1.jpg]" class="mycode_img" /></a><br />
<a href="https://postimg.cc/sBnvffkY" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/sBnvffkY/KNX2.jpg" loading="lazy"  alt="[Image: KNX2.jpg]" class="mycode_img" /></a>]]></description>
			<content:encoded><![CDATA[Bonjour,<br />
<br />
Je viens de migrer vers Home assistant depuis Jeedom. J'ai intégré 99% de mes appareils, mais je bute encore sur une chose : mes volets roulants ZigBee  <img src="https://www.knx-fr.com/images/smilies/dodgy.gif" alt="Dodgy" title="Dodgy" class="smilie smilie_14" /><br />
<br />
Ils remontent sur HA via un dongle SLZB-06, aucun problème à ce niveau. <br />
J'arrive à les piloter depuis mes boutons KNX aussi via Node Red, pas de problème particulier non plus.<br />
<br />
Par contre, j'ai un soucis avec le retour d'état sur mes écrans tactiles Schneider Multitouch qui ont affichage visuel type curseurs :<br />
<a href="https://postimg.cc/JD0J4xb6" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/JD0J4xb6/Curseur.jpg" loading="lazy"  alt="[Image: Curseur.jpg]" class="mycode_img" /></a><br />
<br />
Lorsque j'envoie ma commande, le retour d'état ne se fait pas. Plus précisément :<br />
- lorsque je change le position d'un volet sur un écran, la position ne suit pas sur le second (ils pilotent les mêmes volets)<br />
- lorsque je change la position d'un volet sur HA, la position ne suit sur aucun des deux<br />
<br />
Par contre, sur mon moniteur de bus, j'ai bien un groupvalueWrite de la valeur de la position du volet qui remonte sur mon GA.<br />
<br />
Je pense qu'il doit y avoir un problème au niveau de ma config de retour d'état sur Node Red, et le bus KNX ne doit pas lire/recevoir l'info correctement. Mais étant clairement novice sur HA, je sèche :/<br />
<br />
Je vous mets mes GA depuis ETS (pour un volet, mais identique pour tous) :<br />
<img src="https://i.postimg.cc/q75FWGf5/GA-ETS.jpg" loading="lazy"  alt="[Image: GA-ETS.jpg]" class="mycode_img" /><br />
Et ma config sous Node Red :<br />
<img src="https://i.postimg.cc/htJG7c8m/Node-red.jpg" loading="lazy"  alt="[Image: Node-red.jpg]" class="mycode_img" /><br />
<br />
Et mes noeuds :<br />
<br />
Event : states<br />
[img]<a href="https://i.postimg.cc/9RK0T8FW" target="_blank" rel="noopener" class="mycode_url">https://i.postimg.cc/9RK0T8FW/Event-1.jpg</a>[/img]<br />
[img]<a href="https://i.postimg.cc/r03sWny7/Event-2.jpg" target="_blank" rel="noopener" class="mycode_url">https://i.postimg.cc/r03sWny7/Event-2.jpg</a>[/img]<br />
<br />
Change :<br />
<a href="https://postimg.cc/G8H94wRZ" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/G8H94wRZ/Change.jpg" loading="lazy"  alt="[Image: Change.jpg]" class="mycode_img" /></a><br />
<br />
<br />
KNX Device :<br />
<a href="https://postimg.cc/ph4r8GV4" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/ph4r8GV4/KNX1.jpg" loading="lazy"  alt="[Image: KNX1.jpg]" class="mycode_img" /></a><br />
<a href="https://postimg.cc/sBnvffkY" target="_blank" rel="noopener" class="mycode_url"><img src="https://i.postimg.cc/sBnvffkY/KNX2.jpg" loading="lazy"  alt="[Image: KNX2.jpg]" class="mycode_img" /></a>]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Rénovation maison 175 m² – Projet KNX complet (avis sur architecture et matériel)]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13183</link>
			<pubDate>Mon, 30 Mar 2026 11:04:36 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=9864">akito63</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13183</guid>
			<description><![CDATA[Bonjour à tous,<br />
<br />
Après un long moment de lecture silencieuse, je me lance enfin pour me présenter<br />
Je suis administrateur systèmes et réseaux. J’ai commencé la domotique avec des solutions grand public (Zigbee / Wi-Fi / Bluetooth, type Aqara) dans l’appartement actuel. Un ami m’a ensuite parlé d’une installation KNX, ce qui m’a donné envie d’aller plus loin. Cela fait maintenant un peu plus d’un an que je parcours ce forum : vos retours d’expérience, avis techniques et présentations d’installations m’ont énormément aidé dans la conception de mon projet. Merci à tous.<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Le projet</span></span><br />
Avec ma conjointe, nous avons acheté une maison à étage de 1970, de 175 m² habitables, avec 55 m² de garage, actuellement en rénovation complète. Nous avons conservé uniquement les murs porteurs. Nous réalisons une grande partie des travaux nous-mêmes, ce qui me permet de concevoir une installation électrique et domotique pensée KNX dès le départ.<br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Réflexion KNX / DALI</span></span><br />
Je me suis intéressé au DALI, notamment parce que plusieurs membres du forum l’utilisent.  Après étude, je n’ai finalement pas retenu cette solution pour le moment : je pense comprendre son intérêt, mais au vu de mon <span style="font-weight: bold;" class="mycode_b">budget</span> et du nombre limité de points réellement dimmables,<span style="font-weight: bold;" class="mycode_b"> le KNX me semble plus cohérent dans mon cas.</span><br />
Je suis conscient que les possibilités ne sont pas strictement équivalentes, et que le DALI est probablement plus pertinent à grande échelle. À niveau de prestation équivalent, il me semble également plus coûteux (corrigez-moi si je me trompe).<br />
<br />
<span style="font-size: large;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Tirages électriques et bus</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">Prises classiques :</span> 3G2,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises pilotables :</span> selon les besoins<br />
- Majoritairement en 3G1,5<br />
- Quelques-uns en 3G2,5 et 5G1,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises pilotables avec mesure de consommation :</span><br />
- 3G1,5 / 3G2,5 / 5G1,5 / 5G2,5 selon les usages<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Éclairage :</span> 3G1,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Bus KNX :</span><br />
- Topologie mixte (ligne, étoile ponctuelle, sans boucle fermée)<br />
- Câble YCYM / HCHM 2x2x0,8 <br />
- Passage dans tous les doublages/cloisons à ~1,20 m<br />
- Passage au centre des plafonds afin d’anticiper des évolutions futures<br />
</li>
</ul>
<br />
<span style="font-size: large;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Objectifs et besoins</span></span><br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: medium;" class="mycode_size">Éclairage</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">45 points lumineux</span><br />
- 37 ON/OFF<br />
- 4 dimmables<br />
- 4 rubans LED COB CCT dimmable<br />
</li>
</ul>
<span style="font-size: medium;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Commandes et détection</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">23 interrupteurs</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">14 détecteurs de présence</span><br />
- 8 intérieurs plafond<br />
- 2 intérieurs pour escaliers<br />
- 4 extérieurs<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: medium;" class="mycode_size">Autres fonctions</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">Prises commandées ON/OFF : 18</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises commandées avec mesure de consommation : 12</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion sèche-serviettes : 3</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion PAC air/air gainable Mitsubishi / Airzone</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion alarme</span><br />
- Centrale envisagée : Paradox EVO HD+<br />
- Environ 7 DM et 35 DO<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion porte de garage</span><br />
- Moteur Somfy Dexxo Compact 600 io<br />
- Commande par contact sec envisagée (tests à prévoir)<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion énergie / consommations</span><br />
- Électricité : Linky + certains circuits<br />
- Eau : 2 compteurs d’eau<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion des volets</span><br />
- 13 volets coulissants<br />
- 1 store banne<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion VMC hygroréglable simple flux</span><br />
- Bouton VMC cuisine grande vitesse<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Matériel envisagé / déjà acheté</span></span><br />
<span style="font-weight: bold;" class="mycode_b">Alimentations KNX</span><ul class="mycode_list"><li>Principale : 1x <a href="https://www.voltus.de/mdt-stc-0640-01-knx-busspannungsversorgung-640-ma-diagnosefunktion.html" target="_blank" rel="noopener" class="mycode_url">MDT STC-0640.01</a><br />
</li>
<li>Secours : 1x <a href="https://www.voltus.de/meanwell-knx-20e-640-knx-busspannungsversorgung-640-ma.html" target="_blank" rel="noopener" class="mycode_url">MeanWell KNX-20E-640</a><br />
</li>
<li>Rubans LED : 4x <a href="https://www.voltus.de/meanwell-hlg-185h-24a-hlg-24-v-led-schaltnetzteil-185-w.html" target="_blank" rel="noopener" class="mycode_url">MeanWell HLG-185H-24A</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: small;" class="mycode_size">Interface IP</span></span><ul class="mycode_list"><li>1x <a href="https://www.voltus.de/mdt-scn-ip000-03-knx-ip-schnittstelle-reg.html" target="_blank" rel="noopener" class="mycode_url">MDT SCN-IP000.03</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: small;" class="mycode_size">Détecteurs de présence</span></span><ul class="mycode_list"><li>Plafond intérieur :<br />
- 8x <a href="https://www.voltus.de/busch-jaeger-6131-21-24-knx-praesenzmelder-8-m-mini-premium-studioweiss-matt.html" target="_blank" rel="noopener" class="mycode_url">Busch-Jaeger 6131/21-24</a> ou ABB Mini Premium 6131/21<br />
</li>
<li>Extérieur :<br />
- 4x <a href="https://www.voltus.de/theben-theluxa-p300-knx-wh-knx-bewegungsmelder-weiss.html" target="_blank" rel="noopener" class="mycode_url">TheLuxa P300 KNX</a><br />
</li>
</ul>
<ul class="mycode_list"><li>Escaliers (en angle) :<br />
- 2x <a href="https://www.voltus.de/mdt-scn-bwm55t-02-bewegungsmelder-55-mit-temperatursensor-reinweiss-matt.html" target="_blank" rel="noopener" class="mycode_url">MDT SCN-BWM55T.02</a> (un en bas, un en haut – ouvert à suggestions)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Éclairage</span><ul class="mycode_list"><li>Actionneurs ON/OFF :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-2416-03-knx-schaltaktor-standard-16-a-24-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.2416.03</a><br />
- 1x <a href="https://www.voltus.de/mdt-aks-1616-03-knx-schaltaktor-standard-16-a-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.1616.03</a><br />
</li>
<li>Actionneurs dimmables :<br />
- 1x <a href="https://www.voltus.de/theben-dmg-2-t-knx-dimmaktor-mix-2-fach-grundmodul.html" target="_blank" rel="noopener" class="mycode_url">Theben DMG 2 T KNX</a><br />
- 1x <a href="https://www.voltus.de/theben-dme-2-t-knx-dimmaktor-mix-2-fach-erweiterungsmodul.html" target="_blank" rel="noopener" class="mycode_url">Theben DME 2 T KNX</a><br />
</li>
<li>RGB :<br />
- 1x <a href="https://www.voltus.de/zennio-zdilx4v2-knx-led-dimmaktor-reg-4-fach-secure.html" target="_blank" rel="noopener" class="mycode_url">Zennio Lumento X4 v2</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Prises de courant</span><ul class="mycode_list"><li>ON/OFF :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-2416-03-knx-schaltaktor-standard-16-a-24-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.2416.03</a><br />
</li>
<li>Avec mesure :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-1210-03-knx-schaltaktor-standard-10-a-12-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AMI.1220.03</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Interrupteurs</span><ul class="mycode_list"><li>21x <a href="https://www.voltus.de/jung-ls52941st-knx-tastsensor-f50-serie-ls-4-fach-universal-secure.html" target="_blank" rel="noopener" class="mycode_url">Jung F50 LS LS52941ST</a><br />
</li>
<li>2x   <a href="https://www.voltus.de/jung-ls5094tsem-tastsensor-erweiterungsmodul-f50-ls-4-fach.html" target="_blank" rel="noopener" class="mycode_url">Jung F50 LS LS5094TSEM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls504tsaswm-tastensatz-f50-serie-ls-4-fach-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Boutons Jung LS504TSASWM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls50naswm-schriftfeldabdeckung-f50-serie-ls-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Cache central LS50NASWM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls981swm-abdeckrahmen-ls-990-1-fach-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Cadre LS981SWM</a><br />
</li>
</ul>
<br />
À la suite derniers échanges sur le forum, j’ai regardé d’autres modèles qui sont séduisants aussi :<ul class="mycode_list"><li><a href="https://www.voltus.de/merten-meg6194-6010s-knx-tastsensor-flex-system-design-4-fach-secure-schwarz.html" target="_blank" rel="noopener" class="mycode_url">MEG6194-6010S</a><br />
</li>
<li><a href="https://www.voltus.de/mdt-be-gt2tw-02-knx-glastaster-ii-smart-temperatursensor-glas-weiss.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-GT2TW.02</a><br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Volets</span><ul class="mycode_list"><li>2x <a href="https://www.voltus.de/abb-jra-s8-230-5-2-knx-jalousieaktor-230-v-8-fach-manuelle-bedienung-fahrtzeitmessung.html" target="_blank" rel="noopener" class="mycode_url">ABB JRA/S8.230.5.2</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Sèche-serviettes</span><ul class="mycode_list"><li>2x <a href="http://www.proknx.com/fr/product/fil-pilote/" target="_blank" rel="noopener" class="mycode_url">Fil pilote BleuComm’Azur</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">PAC Airzone</span><ul class="mycode_list"><li>1x <a href="https://www.light-domotique.fr/Airzone-Passerelle%2520d'int%C3%A9gration%2520KNX-Airzone%2520X6%2520-%2520AZX6KNXGTWAY" target="_blank" rel="noopener" class="mycode_url">Passerelle Airzone/KNX AZX6KNXGTWAY</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Comptage énergie</span><ul class="mycode_list"><li>1x <a href="https://www.voltus.de/hager-te332-knx-easy-messwertgeber-3-fach-inkl-wandler.html" target="_blank" rel="noopener" class="mycode_url">Hager TE332</a><br />
</li>
<li>1x <a href="https://www.voltus.de/hager-txe773-knx-impuls-gateway-3-fach.html" target="_blank" rel="noopener" class="mycode_url">Hager TXE773</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Entrées binaires</span><ul class="mycode_list"><li><a href="https://www.voltus.de/abb-uk-s32-2-knx-e-a-konzentrator-32-fach.html" target="_blank" rel="noopener" class="mycode_url">ABB UK/S32.2</a> ou/et <a href="https://www.voltus.de/mdt-be-16000-02-knx-binaereingang-potentialfrei-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-16000.02</a> (choix à finaliser)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Alarme</span><ul class="mycode_list"><li><a href="https://www.planete-alarme.com/alarme-paradox-evohd-centrale-filaire-paradox-244.html" target="_blank" rel="noopener" class="mycode_url">Paradox EVO HD+</a><br />
</li>
<li><a href="https://elausys.com/pt/produtos/interface-paradox-knx-evo-knx" target="_blank" rel="noopener" class="mycode_url">Interface PARADOX KNX</a><br />
</li>
<li>35 x Détecteur d’ouverture / Reeds (<a href="https://www.eas-alarme-services.fr/intrusion.php?article=IM1340FE" target="_blank" rel="noopener" class="mycode_url">IM1340FE</a> et <a href="https://alarmtechglobal.com/fr/produit/mc-740-pe/" target="_blank" rel="noopener" class="mycode_url">MC 740-PE</a>)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Tableau électrique</span><ul class="mycode_list"><li>1x <a href="https://www.f-tronic.de/datasheets/EN/DB_7110232_FV4-6_EN.pdf" target="_blank" rel="noopener" class="mycode_url">F-tonic FV4-6</a> (288 modules)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Licence</span><ul class="mycode_list"><li>ETS Home (passage à ETS Pro prévu si nécessaire)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Vidéo / réseau</span><ul class="mycode_list"><li>Visiophone : <a href="https://eu.store.ui.com/eu/en/category/cameras-doorbells/collections/pro-store-doorbells-chimes/products/uvc-g4-doorbell-pro-poe-kit" target="_blank" rel="noopener" class="mycode_url">Ubiquiti G4 Doorbell Pro PoE</a><br />
</li>
<li>Caméras : Hikvision ou Dahua (6 extérieures, 2 intérieures) avec NVR<br />
</li>
<li>Wifi : je pense partir sur 3 bornes U7 Pro XG/XGS de Unifi<br />
</li>
<li>Baie informatique :<br />
- J’ai deux baies une 42U 80x60 et la dernière achetée une 24U 60x60 , que je pense garder- 36 arrivées RJ45 Cat 6A- Switches à définir (matériel temporaire au départ)<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Évolutions prévues (second temps)</span><ul class="mycode_list"><li>Alimentation DIN <a href="https://www.voltus.de/meanwell-hdr-15-24-hdr-24-v-schaltnetzteil-15-w.html" target="_blank" rel="noopener" class="mycode_url">HDR-15-24</a><br />
</li>
<li>Module logique <a href="https://www.voltus.de/abb-aba-s1-2-1-knx-logik-controller-standard.html" target="_blank" rel="noopener" class="mycode_url">ABB ABA/S1.2.1</a><br />
</li>
<li>Alimentation dédiée station météo <a href="https://www.voltus.de/meanwell-hdr-15-24-hdr-24-v-schaltnetzteil-15-w.html" target="_blank" rel="noopener" class="mycode_url">HDR-15-24</a><br />
</li>
<li>Station météo <a href="https://www.voltus.de/jung-2225wsu-knx-wetterstation-universal.html" target="_blank" rel="noopener" class="mycode_url">Jung 2225 WS U</a><br />
? Maison avec toit 4 pans, implantation encore à définir<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">❓ Questions</span><br />
<span style="font-weight: bold;" class="mycode_b">1) Commande de pompe à eau (cuve à eau</span>) <br />
À la suite d’une remarque @Ives sur le forum concernant le courant de démarrage des pompes :<ul class="mycode_list"><li>Pour une pompe à eau, un actionneur MDT AMI est-il suffisant ?<br />
</li>
<li>Ou faut-il impérativement passer par un contacteur de puissance piloté en KNX ?<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">2) Entrées binaires</span><br />
 Pour mes besoins (contact Reed porte de garage, contact reed porte d’entrée, etc), j’hésite entre :<ul class="mycode_list"><li><a href="https://www.voltus.de/abb-uk-s32-2-knx-e-a-konzentrator-32-fach.html" target="_blank" rel="noopener" class="mycode_url">ABB UK/S32.2</a><br />
</li>
<li><a href="https://www.voltus.de/mdt-be-16000-02-knx-binaereingang-potentialfrei-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-16000.02</a>  <br />
</li>
</ul>
Avez-vous des retours d’expérience ou autres recommandations ?<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b">3) Interrupteur</span><br />
J’ai lu sur le forum qu’il serait possible de prendre des interrupteurs 4 voies et de choisir les boutons en conséquence pour les transformer en interrupteurs 2 voies, soit avec 4 boutons, ou 1 voie avec 2 boutons. Si quelqu’un peut me confirmer ?<br />
<br />
Quelle est la bonne pratique pour les interrupteurs ? Par exemple, dans la cuisine, j’ai différentes choses à contrôler : le volet roulant, la lumière principale, la lumière de la table à manger, la lumière du plan de travail et la VMC. Comment feriez-vous, mettre genre une lumière sur 1 bouton en mode toogle/switch ou une fonction par bouton mais cela impliquerait d’avoir un autre bouton.<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b">4) Confirmation</span><br />
Afin de commander mes besoins suivants, il faut bien des actionneurs car les entrées ne peuvent pas actionner un contact sec :<ul class="mycode_list"><li>Pour la bouche de ma cuisine, C’est une Aldes Hygroréglable Type B simple flux. Il y a un bouton poussoir pour mettre un débit plus élevé avec une temporisation.<br />
</li>
<li>Pour le moteur de ma porte de garage (Somfy Dexxo 600 io Compact) :  il y aurait un contact d’après la doc<br />
</li>
<li>Pour le moteur du portail : je n’ai pas choisi mais je prévoie<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Documentation disponible</span><br />
Plans et documents récapitulatif disponibles (tableau, organisation générale).<br />
Schéma unifilaire et positionnement des borniers Wago en cours.<br />
Autres documents fournis sur demande si besoin de précisions.<br />
<br />
Je continuerai à <span style="font-weight: bold;" class="mycode_b">alimenter ce sujet au fil de l’avancement des travaux.</span><br />
Je suis actuellement en train de <span style="font-weight: bold;" class="mycode_b">tirer les câbles KNX et électriques</span>, avec un objectif de <span style="font-weight: bold;" class="mycode_b">pose des doublages d’ici fin avril.</span><br />
<br />
Merci d’avance pour votre lecture et vos retours. Je suis preneur de toutes remarques ou critiques constructives, dans l’objectif d’améliorer l’installation avant sa mise en service.<br />
N’hésitez pas à me dire si vous voyez <span style="font-weight: bold;" class="mycode_b">une erreur de conception</span>, je préfère corriger maintenant avant fermeture des cloisons.<br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3051" target="_blank" title="">Plan 1ER.pdf</a> (Taille : 763,36 Ko / Téléchargements : 12)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3052" target="_blank" title="">Plan RDC.pdf</a> (Taille : 442,15 Ko / Téléchargements : 7)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3053" target="_blank" title="">Tableau Elec.pdf</a> (Taille : 165,52 Ko / Téléchargements : 8)
<!-- end: postbit_attachments_attachment -->]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
<br />
Après un long moment de lecture silencieuse, je me lance enfin pour me présenter<br />
Je suis administrateur systèmes et réseaux. J’ai commencé la domotique avec des solutions grand public (Zigbee / Wi-Fi / Bluetooth, type Aqara) dans l’appartement actuel. Un ami m’a ensuite parlé d’une installation KNX, ce qui m’a donné envie d’aller plus loin. Cela fait maintenant un peu plus d’un an que je parcours ce forum : vos retours d’expérience, avis techniques et présentations d’installations m’ont énormément aidé dans la conception de mon projet. Merci à tous.<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Le projet</span></span><br />
Avec ma conjointe, nous avons acheté une maison à étage de 1970, de 175 m² habitables, avec 55 m² de garage, actuellement en rénovation complète. Nous avons conservé uniquement les murs porteurs. Nous réalisons une grande partie des travaux nous-mêmes, ce qui me permet de concevoir une installation électrique et domotique pensée KNX dès le départ.<br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Réflexion KNX / DALI</span></span><br />
Je me suis intéressé au DALI, notamment parce que plusieurs membres du forum l’utilisent.  Après étude, je n’ai finalement pas retenu cette solution pour le moment : je pense comprendre son intérêt, mais au vu de mon <span style="font-weight: bold;" class="mycode_b">budget</span> et du nombre limité de points réellement dimmables,<span style="font-weight: bold;" class="mycode_b"> le KNX me semble plus cohérent dans mon cas.</span><br />
Je suis conscient que les possibilités ne sont pas strictement équivalentes, et que le DALI est probablement plus pertinent à grande échelle. À niveau de prestation équivalent, il me semble également plus coûteux (corrigez-moi si je me trompe).<br />
<br />
<span style="font-size: large;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Tirages électriques et bus</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">Prises classiques :</span> 3G2,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises pilotables :</span> selon les besoins<br />
- Majoritairement en 3G1,5<br />
- Quelques-uns en 3G2,5 et 5G1,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises pilotables avec mesure de consommation :</span><br />
- 3G1,5 / 3G2,5 / 5G1,5 / 5G2,5 selon les usages<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Éclairage :</span> 3G1,5<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Bus KNX :</span><br />
- Topologie mixte (ligne, étoile ponctuelle, sans boucle fermée)<br />
- Câble YCYM / HCHM 2x2x0,8 <br />
- Passage dans tous les doublages/cloisons à ~1,20 m<br />
- Passage au centre des plafonds afin d’anticiper des évolutions futures<br />
</li>
</ul>
<br />
<span style="font-size: large;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Objectifs et besoins</span></span><br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: medium;" class="mycode_size">Éclairage</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">45 points lumineux</span><br />
- 37 ON/OFF<br />
- 4 dimmables<br />
- 4 rubans LED COB CCT dimmable<br />
</li>
</ul>
<span style="font-size: medium;" class="mycode_size"><span style="font-weight: bold;" class="mycode_b">Commandes et détection</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">23 interrupteurs</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">14 détecteurs de présence</span><br />
- 8 intérieurs plafond<br />
- 2 intérieurs pour escaliers<br />
- 4 extérieurs<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: medium;" class="mycode_size">Autres fonctions</span></span><ul class="mycode_list"><li><span style="font-weight: bold;" class="mycode_b">Prises commandées ON/OFF : 18</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Prises commandées avec mesure de consommation : 12</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion sèche-serviettes : 3</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion PAC air/air gainable Mitsubishi / Airzone</span><br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion alarme</span><br />
- Centrale envisagée : Paradox EVO HD+<br />
- Environ 7 DM et 35 DO<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion porte de garage</span><br />
- Moteur Somfy Dexxo Compact 600 io<br />
- Commande par contact sec envisagée (tests à prévoir)<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion énergie / consommations</span><br />
- Électricité : Linky + certains circuits<br />
- Eau : 2 compteurs d’eau<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion des volets</span><br />
- 13 volets coulissants<br />
- 1 store banne<br />
</li>
<li><span style="font-weight: bold;" class="mycode_b">Gestion VMC hygroréglable simple flux</span><br />
- Bouton VMC cuisine grande vitesse<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: large;" class="mycode_size">Matériel envisagé / déjà acheté</span></span><br />
<span style="font-weight: bold;" class="mycode_b">Alimentations KNX</span><ul class="mycode_list"><li>Principale : 1x <a href="https://www.voltus.de/mdt-stc-0640-01-knx-busspannungsversorgung-640-ma-diagnosefunktion.html" target="_blank" rel="noopener" class="mycode_url">MDT STC-0640.01</a><br />
</li>
<li>Secours : 1x <a href="https://www.voltus.de/meanwell-knx-20e-640-knx-busspannungsversorgung-640-ma.html" target="_blank" rel="noopener" class="mycode_url">MeanWell KNX-20E-640</a><br />
</li>
<li>Rubans LED : 4x <a href="https://www.voltus.de/meanwell-hlg-185h-24a-hlg-24-v-led-schaltnetzteil-185-w.html" target="_blank" rel="noopener" class="mycode_url">MeanWell HLG-185H-24A</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: small;" class="mycode_size">Interface IP</span></span><ul class="mycode_list"><li>1x <a href="https://www.voltus.de/mdt-scn-ip000-03-knx-ip-schnittstelle-reg.html" target="_blank" rel="noopener" class="mycode_url">MDT SCN-IP000.03</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b"><span style="font-size: small;" class="mycode_size">Détecteurs de présence</span></span><ul class="mycode_list"><li>Plafond intérieur :<br />
- 8x <a href="https://www.voltus.de/busch-jaeger-6131-21-24-knx-praesenzmelder-8-m-mini-premium-studioweiss-matt.html" target="_blank" rel="noopener" class="mycode_url">Busch-Jaeger 6131/21-24</a> ou ABB Mini Premium 6131/21<br />
</li>
<li>Extérieur :<br />
- 4x <a href="https://www.voltus.de/theben-theluxa-p300-knx-wh-knx-bewegungsmelder-weiss.html" target="_blank" rel="noopener" class="mycode_url">TheLuxa P300 KNX</a><br />
</li>
</ul>
<ul class="mycode_list"><li>Escaliers (en angle) :<br />
- 2x <a href="https://www.voltus.de/mdt-scn-bwm55t-02-bewegungsmelder-55-mit-temperatursensor-reinweiss-matt.html" target="_blank" rel="noopener" class="mycode_url">MDT SCN-BWM55T.02</a> (un en bas, un en haut – ouvert à suggestions)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Éclairage</span><ul class="mycode_list"><li>Actionneurs ON/OFF :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-2416-03-knx-schaltaktor-standard-16-a-24-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.2416.03</a><br />
- 1x <a href="https://www.voltus.de/mdt-aks-1616-03-knx-schaltaktor-standard-16-a-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.1616.03</a><br />
</li>
<li>Actionneurs dimmables :<br />
- 1x <a href="https://www.voltus.de/theben-dmg-2-t-knx-dimmaktor-mix-2-fach-grundmodul.html" target="_blank" rel="noopener" class="mycode_url">Theben DMG 2 T KNX</a><br />
- 1x <a href="https://www.voltus.de/theben-dme-2-t-knx-dimmaktor-mix-2-fach-erweiterungsmodul.html" target="_blank" rel="noopener" class="mycode_url">Theben DME 2 T KNX</a><br />
</li>
<li>RGB :<br />
- 1x <a href="https://www.voltus.de/zennio-zdilx4v2-knx-led-dimmaktor-reg-4-fach-secure.html" target="_blank" rel="noopener" class="mycode_url">Zennio Lumento X4 v2</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Prises de courant</span><ul class="mycode_list"><li>ON/OFF :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-2416-03-knx-schaltaktor-standard-16-a-24-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AKS.2416.03</a><br />
</li>
<li>Avec mesure :<br />
- 1x <a href="https://www.voltus.de/mdt-aks-1210-03-knx-schaltaktor-standard-10-a-12-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT AMI.1220.03</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Interrupteurs</span><ul class="mycode_list"><li>21x <a href="https://www.voltus.de/jung-ls52941st-knx-tastsensor-f50-serie-ls-4-fach-universal-secure.html" target="_blank" rel="noopener" class="mycode_url">Jung F50 LS LS52941ST</a><br />
</li>
<li>2x   <a href="https://www.voltus.de/jung-ls5094tsem-tastsensor-erweiterungsmodul-f50-ls-4-fach.html" target="_blank" rel="noopener" class="mycode_url">Jung F50 LS LS5094TSEM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls504tsaswm-tastensatz-f50-serie-ls-4-fach-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Boutons Jung LS504TSASWM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls50naswm-schriftfeldabdeckung-f50-serie-ls-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Cache central LS50NASWM</a><br />
</li>
<li>23x <a href="https://www.voltus.de/jung-ls981swm-abdeckrahmen-ls-990-1-fach-graphitschwarz-matt.html" target="_blank" rel="noopener" class="mycode_url">Cadre LS981SWM</a><br />
</li>
</ul>
<br />
À la suite derniers échanges sur le forum, j’ai regardé d’autres modèles qui sont séduisants aussi :<ul class="mycode_list"><li><a href="https://www.voltus.de/merten-meg6194-6010s-knx-tastsensor-flex-system-design-4-fach-secure-schwarz.html" target="_blank" rel="noopener" class="mycode_url">MEG6194-6010S</a><br />
</li>
<li><a href="https://www.voltus.de/mdt-be-gt2tw-02-knx-glastaster-ii-smart-temperatursensor-glas-weiss.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-GT2TW.02</a><br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Volets</span><ul class="mycode_list"><li>2x <a href="https://www.voltus.de/abb-jra-s8-230-5-2-knx-jalousieaktor-230-v-8-fach-manuelle-bedienung-fahrtzeitmessung.html" target="_blank" rel="noopener" class="mycode_url">ABB JRA/S8.230.5.2</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Sèche-serviettes</span><ul class="mycode_list"><li>2x <a href="http://www.proknx.com/fr/product/fil-pilote/" target="_blank" rel="noopener" class="mycode_url">Fil pilote BleuComm’Azur</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">PAC Airzone</span><ul class="mycode_list"><li>1x <a href="https://www.light-domotique.fr/Airzone-Passerelle%2520d'int%C3%A9gration%2520KNX-Airzone%2520X6%2520-%2520AZX6KNXGTWAY" target="_blank" rel="noopener" class="mycode_url">Passerelle Airzone/KNX AZX6KNXGTWAY</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Comptage énergie</span><ul class="mycode_list"><li>1x <a href="https://www.voltus.de/hager-te332-knx-easy-messwertgeber-3-fach-inkl-wandler.html" target="_blank" rel="noopener" class="mycode_url">Hager TE332</a><br />
</li>
<li>1x <a href="https://www.voltus.de/hager-txe773-knx-impuls-gateway-3-fach.html" target="_blank" rel="noopener" class="mycode_url">Hager TXE773</a><br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Entrées binaires</span><ul class="mycode_list"><li><a href="https://www.voltus.de/abb-uk-s32-2-knx-e-a-konzentrator-32-fach.html" target="_blank" rel="noopener" class="mycode_url">ABB UK/S32.2</a> ou/et <a href="https://www.voltus.de/mdt-be-16000-02-knx-binaereingang-potentialfrei-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-16000.02</a> (choix à finaliser)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Alarme</span><ul class="mycode_list"><li><a href="https://www.planete-alarme.com/alarme-paradox-evohd-centrale-filaire-paradox-244.html" target="_blank" rel="noopener" class="mycode_url">Paradox EVO HD+</a><br />
</li>
<li><a href="https://elausys.com/pt/produtos/interface-paradox-knx-evo-knx" target="_blank" rel="noopener" class="mycode_url">Interface PARADOX KNX</a><br />
</li>
<li>35 x Détecteur d’ouverture / Reeds (<a href="https://www.eas-alarme-services.fr/intrusion.php?article=IM1340FE" target="_blank" rel="noopener" class="mycode_url">IM1340FE</a> et <a href="https://alarmtechglobal.com/fr/produit/mc-740-pe/" target="_blank" rel="noopener" class="mycode_url">MC 740-PE</a>)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Tableau électrique</span><ul class="mycode_list"><li>1x <a href="https://www.f-tronic.de/datasheets/EN/DB_7110232_FV4-6_EN.pdf" target="_blank" rel="noopener" class="mycode_url">F-tonic FV4-6</a> (288 modules)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Licence</span><ul class="mycode_list"><li>ETS Home (passage à ETS Pro prévu si nécessaire)<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">Vidéo / réseau</span><ul class="mycode_list"><li>Visiophone : <a href="https://eu.store.ui.com/eu/en/category/cameras-doorbells/collections/pro-store-doorbells-chimes/products/uvc-g4-doorbell-pro-poe-kit" target="_blank" rel="noopener" class="mycode_url">Ubiquiti G4 Doorbell Pro PoE</a><br />
</li>
<li>Caméras : Hikvision ou Dahua (6 extérieures, 2 intérieures) avec NVR<br />
</li>
<li>Wifi : je pense partir sur 3 bornes U7 Pro XG/XGS de Unifi<br />
</li>
<li>Baie informatique :<br />
- J’ai deux baies une 42U 80x60 et la dernière achetée une 24U 60x60 , que je pense garder- 36 arrivées RJ45 Cat 6A- Switches à définir (matériel temporaire au départ)<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Évolutions prévues (second temps)</span><ul class="mycode_list"><li>Alimentation DIN <a href="https://www.voltus.de/meanwell-hdr-15-24-hdr-24-v-schaltnetzteil-15-w.html" target="_blank" rel="noopener" class="mycode_url">HDR-15-24</a><br />
</li>
<li>Module logique <a href="https://www.voltus.de/abb-aba-s1-2-1-knx-logik-controller-standard.html" target="_blank" rel="noopener" class="mycode_url">ABB ABA/S1.2.1</a><br />
</li>
<li>Alimentation dédiée station météo <a href="https://www.voltus.de/meanwell-hdr-15-24-hdr-24-v-schaltnetzteil-15-w.html" target="_blank" rel="noopener" class="mycode_url">HDR-15-24</a><br />
</li>
<li>Station météo <a href="https://www.voltus.de/jung-2225wsu-knx-wetterstation-universal.html" target="_blank" rel="noopener" class="mycode_url">Jung 2225 WS U</a><br />
? Maison avec toit 4 pans, implantation encore à définir<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">❓ Questions</span><br />
<span style="font-weight: bold;" class="mycode_b">1) Commande de pompe à eau (cuve à eau</span>) <br />
À la suite d’une remarque @Ives sur le forum concernant le courant de démarrage des pompes :<ul class="mycode_list"><li>Pour une pompe à eau, un actionneur MDT AMI est-il suffisant ?<br />
</li>
<li>Ou faut-il impérativement passer par un contacteur de puissance piloté en KNX ?<br />
</li>
</ul>
<span style="font-weight: bold;" class="mycode_b">2) Entrées binaires</span><br />
 Pour mes besoins (contact Reed porte de garage, contact reed porte d’entrée, etc), j’hésite entre :<ul class="mycode_list"><li><a href="https://www.voltus.de/abb-uk-s32-2-knx-e-a-konzentrator-32-fach.html" target="_blank" rel="noopener" class="mycode_url">ABB UK/S32.2</a><br />
</li>
<li><a href="https://www.voltus.de/mdt-be-16000-02-knx-binaereingang-potentialfrei-16-fach.html" target="_blank" rel="noopener" class="mycode_url">MDT BE-16000.02</a>  <br />
</li>
</ul>
Avez-vous des retours d’expérience ou autres recommandations ?<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b">3) Interrupteur</span><br />
J’ai lu sur le forum qu’il serait possible de prendre des interrupteurs 4 voies et de choisir les boutons en conséquence pour les transformer en interrupteurs 2 voies, soit avec 4 boutons, ou 1 voie avec 2 boutons. Si quelqu’un peut me confirmer ?<br />
<br />
Quelle est la bonne pratique pour les interrupteurs ? Par exemple, dans la cuisine, j’ai différentes choses à contrôler : le volet roulant, la lumière principale, la lumière de la table à manger, la lumière du plan de travail et la VMC. Comment feriez-vous, mettre genre une lumière sur 1 bouton en mode toogle/switch ou une fonction par bouton mais cela impliquerait d’avoir un autre bouton.<br />
<br />
<br />
<span style="font-weight: bold;" class="mycode_b">4) Confirmation</span><br />
Afin de commander mes besoins suivants, il faut bien des actionneurs car les entrées ne peuvent pas actionner un contact sec :<ul class="mycode_list"><li>Pour la bouche de ma cuisine, C’est une Aldes Hygroréglable Type B simple flux. Il y a un bouton poussoir pour mettre un débit plus élevé avec une temporisation.<br />
</li>
<li>Pour le moteur de ma porte de garage (Somfy Dexxo 600 io Compact) :  il y aurait un contact d’après la doc<br />
</li>
<li>Pour le moteur du portail : je n’ai pas choisi mais je prévoie<br />
</li>
</ul>
<br />
<span style="font-weight: bold;" class="mycode_b">Documentation disponible</span><br />
Plans et documents récapitulatif disponibles (tableau, organisation générale).<br />
Schéma unifilaire et positionnement des borniers Wago en cours.<br />
Autres documents fournis sur demande si besoin de précisions.<br />
<br />
Je continuerai à <span style="font-weight: bold;" class="mycode_b">alimenter ce sujet au fil de l’avancement des travaux.</span><br />
Je suis actuellement en train de <span style="font-weight: bold;" class="mycode_b">tirer les câbles KNX et électriques</span>, avec un objectif de <span style="font-weight: bold;" class="mycode_b">pose des doublages d’ici fin avril.</span><br />
<br />
Merci d’avance pour votre lecture et vos retours. Je suis preneur de toutes remarques ou critiques constructives, dans l’objectif d’améliorer l’installation avant sa mise en service.<br />
N’hésitez pas à me dire si vous voyez <span style="font-weight: bold;" class="mycode_b">une erreur de conception</span>, je préfère corriger maintenant avant fermeture des cloisons.<br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3051" target="_blank" title="">Plan 1ER.pdf</a> (Taille : 763,36 Ko / Téléchargements : 12)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3052" target="_blank" title="">Plan RDC.pdf</a> (Taille : 442,15 Ko / Téléchargements : 7)
<!-- end: postbit_attachments_attachment --><br /><!-- start: postbit_attachments_attachment -->
<br /><!-- start: attachment_icon -->
<img src="https://www.knx-fr.com/images/attachtypes/pdf.gif" title="Adobe Acrobat PDF" border="0" alt=".pdf" />
<!-- end: attachment_icon -->&nbsp;&nbsp;<a href="attachment.php?aid=3053" target="_blank" title="">Tableau Elec.pdf</a> (Taille : 165,52 Ko / Téléchargements : 8)
<!-- end: postbit_attachments_attachment -->]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[KNX Reast API]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13186</link>
			<pubDate>Mon, 30 Mar 2026 10:34:53 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=10826">Smart Guido 73</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13186</guid>
			<description><![CDATA[Bonjour à tous,<br />
<br />
j’ai développé une API REST en ASP.NET qui permet de se connecter à un système KNX (via USB, IP ou KNX IP Secure).<br />
Cette API propose de nombreuses fonctionnalités, notamment :<ul class="mycode_list"><li>WriteBool<br />
</li>
<li>WriteByte<br />
</li>
<li>WriteDPT<br />
</li>
<li>ReadValue<br />
</li>
<li>le chargement des adresses de groupe à partir d’un fichier XML <br />
</li>
<li>ainsi que d’autres commandes utiles pour la communication KNX <br />
</li>
</ul>
<br />
<br />
En outre, tous les endpoints de l’API sont affichés directement sur le serveur avec des explications détaillées, ce qui facilite grandement l’utilisation et l’intégration.<br />
Vous trouverez ci-dessous quelques-unes des principales fonctionnalités et endpoints :<br />
<br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/swagger/index.html" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/swagger/index.html</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connectusb" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connectusb</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connect?ip=192.168.178.42&amp;port=3671&amp;nat=true" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connect?i...1&amp;nat=true</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connectsecure?ip=192.168.178.42&amp;port=3671&amp;nat=true&amp;indiaddress=1.1.241&amp;filename=C:\\keys\\test.kexkeys&amp;password=1234" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connectse...sword=1234</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/dispose" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/dispose</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/readvalue?groupaddress=1/2/10&amp;dpt1=1&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/readvalue...1=1&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writebool?groupaddress=1/2/10&amp;value=true" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writebool...value=true</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writebyte?groupaddress=1/2/10&amp;value=100" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writebyte...&amp;value=100</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writevaluetodpt?groupaddress=1/2/10&amp;value=22.5&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writevalu...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/converttoraw?value=22.5&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/convertto...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/converttodpt?value=0x07D0&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/convertto...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/loaddptlist?filename=C:\\data\\dpt.xml" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/loaddptli...a\\dpt.xml</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/telegrams" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/telegrams</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/check?groupaddress=1/2/10" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/check?gro...ess=1/2/10</a></span><br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="color: #e82a1f;" class="mycode_color">lien de téléchargement:</span></span><br />
<span style="font-weight: bold;" class="mycode_b"><span style="color: #e82a1f;" class="mycode_color"><a href="https://www.knx-board.org/download.php?file=knxwebapiv19.zip" target="_blank" rel="noopener" class="mycode_url">https://www.knx-board.org/download.php?f...apiv19.zip</a></span></span>]]></description>
			<content:encoded><![CDATA[Bonjour à tous,<br />
<br />
j’ai développé une API REST en ASP.NET qui permet de se connecter à un système KNX (via USB, IP ou KNX IP Secure).<br />
Cette API propose de nombreuses fonctionnalités, notamment :<ul class="mycode_list"><li>WriteBool<br />
</li>
<li>WriteByte<br />
</li>
<li>WriteDPT<br />
</li>
<li>ReadValue<br />
</li>
<li>le chargement des adresses de groupe à partir d’un fichier XML <br />
</li>
<li>ainsi que d’autres commandes utiles pour la communication KNX <br />
</li>
</ul>
<br />
<br />
En outre, tous les endpoints de l’API sont affichés directement sur le serveur avec des explications détaillées, ce qui facilite grandement l’utilisation et l’intégration.<br />
Vous trouverez ci-dessous quelques-unes des principales fonctionnalités et endpoints :<br />
<br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/swagger/index.html" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/swagger/index.html</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connectusb" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connectusb</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connect?ip=192.168.178.42&amp;port=3671&amp;nat=true" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connect?i...1&amp;nat=true</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/connectsecure?ip=192.168.178.42&amp;port=3671&amp;nat=true&amp;indiaddress=1.1.241&amp;filename=C:\\keys\\test.kexkeys&amp;password=1234" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/connectse...sword=1234</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/dispose" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/dispose</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/readvalue?groupaddress=1/2/10&amp;dpt1=1&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/readvalue...1=1&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writebool?groupaddress=1/2/10&amp;value=true" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writebool...value=true</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writebyte?groupaddress=1/2/10&amp;value=100" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writebyte...&amp;value=100</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/writevaluetodpt?groupaddress=1/2/10&amp;value=22.5&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/writevalu...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/converttoraw?value=22.5&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/convertto...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/converttodpt?value=0x07D0&amp;dpt1=9&amp;dpt2=1" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/convertto...1=9&amp;dpt2=1</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/loaddptlist?filename=C:\\data\\dpt.xml" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/loaddptli...a\\dpt.xml</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/telegrams" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/telegrams</a></span><br />
<span style="color: #0074d9;" class="mycode_color"><a href="https://localhost:7061/api/knx/check?groupaddress=1/2/10" target="_blank" rel="noopener" class="mycode_url">https://localhost:7061/api/knx/check?gro...ess=1/2/10</a></span><br />
<br />
<span style="font-weight: bold;" class="mycode_b"><span style="color: #e82a1f;" class="mycode_color">lien de téléchargement:</span></span><br />
<span style="font-weight: bold;" class="mycode_b"><span style="color: #e82a1f;" class="mycode_color"><a href="https://www.knx-board.org/download.php?file=knxwebapiv19.zip" target="_blank" rel="noopener" class="mycode_url">https://www.knx-board.org/download.php?f...apiv19.zip</a></span></span>]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Gestion de l'ouverture des volets]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13185</link>
			<pubDate>Sun, 29 Mar 2026 17:35:11 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=8693">vlnk</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13185</guid>
			<description><![CDATA[Bonjour,<br />
<br />
Je suis en train de configurer un module horaire MDT SCN-RTC20.02 dans ETS pour piloter des volets, et je rencontre une limitation que je n’arrive pas à contourner.<br />
<br />
Mon besoin (simplifié) est le suivant :<ul class="mycode_list"><li>Ouvrir un volet au lever du soleil, mais <span style="font-weight: bold;" class="mycode_b">pas avant 08:00</span><br />
</li>
<li>Pour un second volet : ouverture au lever du soleil avec un <span style="font-weight: bold;" class="mycode_b">décalage de +30 min</span>, mais toujours <span style="font-weight: bold;" class="mycode_b">pas avant 08:00<br />
</span><br />
</li>
</ul>
Problème :<br />
Dans le menu “Interrupteur horaire”, il n’est possible de sélectionner qu’une seule condition par ligne (soit “décalage horaire”, soit “le plus tôt à”, etc.).<br />
Je ne peux donc pas combiner :<ul class="mycode_list"><li>un décalage (+30 min)<br />
</li>
<li>ET une contrainte “ le plus tôt à 08:00”<br />
</li>
</ul>
Questions :<br />
<ol type="1" class="mycode_list"><li>Existe-t-il une manière native dans le SCN-RTC20.02 de combiner ces deux conditions ?<br />
</li>
<li>Faut-il obligatoirement passer par un bloc logique (AND entre astro + condition horaire) ?<br />
</li>
<li>Si oui, quelle est la meilleure pratique pour structurer cela proprement dans ETS (objets à utiliser, retour d’état, etc.) ?<br />
</li>
</ol>
Je cherche une solution côté KNX (idéalement sans ajouter de logique externe type serveur).<br />
<br />
Merci d’avance pour vos retours.]]></description>
			<content:encoded><![CDATA[Bonjour,<br />
<br />
Je suis en train de configurer un module horaire MDT SCN-RTC20.02 dans ETS pour piloter des volets, et je rencontre une limitation que je n’arrive pas à contourner.<br />
<br />
Mon besoin (simplifié) est le suivant :<ul class="mycode_list"><li>Ouvrir un volet au lever du soleil, mais <span style="font-weight: bold;" class="mycode_b">pas avant 08:00</span><br />
</li>
<li>Pour un second volet : ouverture au lever du soleil avec un <span style="font-weight: bold;" class="mycode_b">décalage de +30 min</span>, mais toujours <span style="font-weight: bold;" class="mycode_b">pas avant 08:00<br />
</span><br />
</li>
</ul>
Problème :<br />
Dans le menu “Interrupteur horaire”, il n’est possible de sélectionner qu’une seule condition par ligne (soit “décalage horaire”, soit “le plus tôt à”, etc.).<br />
Je ne peux donc pas combiner :<ul class="mycode_list"><li>un décalage (+30 min)<br />
</li>
<li>ET une contrainte “ le plus tôt à 08:00”<br />
</li>
</ul>
Questions :<br />
<ol type="1" class="mycode_list"><li>Existe-t-il une manière native dans le SCN-RTC20.02 de combiner ces deux conditions ?<br />
</li>
<li>Faut-il obligatoirement passer par un bloc logique (AND entre astro + condition horaire) ?<br />
</li>
<li>Si oui, quelle est la meilleure pratique pour structurer cela proprement dans ETS (objets à utiliser, retour d’état, etc.) ?<br />
</li>
</ol>
Je cherche une solution côté KNX (idéalement sans ajouter de logique externe type serveur).<br />
<br />
Merci d’avance pour vos retours.]]></content:encoded>
		</item>
		<item>
			<title><![CDATA[Interface JUNG IPS300SREG]]></title>
			<link>https://www.knx-fr.com/showthread.php?tid=13184</link>
			<pubDate>Sat, 28 Mar 2026 08:32:15 +0000</pubDate>
			<dc:creator><![CDATA[<a href="https://www.knx-fr.com/member.php?action=profile&uid=7278">Mick@</a>]]></dc:creator>
			<guid isPermaLink="false">https://www.knx-fr.com/showthread.php?tid=13184</guid>
			<description><![CDATA[Bonjour, je souhaite changer le programme d'application de l'interface. <br />
Actuellement je suis sur la version V1.0 et je veux installer la version V2.2<br />
Je ne trouve pas d'informations sur le site de JUNG<br />
Par avance merci<br />
Mick@]]></description>
			<content:encoded><![CDATA[Bonjour, je souhaite changer le programme d'application de l'interface. <br />
Actuellement je suis sur la version V1.0 et je veux installer la version V2.2<br />
Je ne trouve pas d'informations sur le site de JUNG<br />
Par avance merci<br />
Mick@]]></content:encoded>